ADROW CHEMICAL CO. -- MERCURY (VARIOUS GRADES) -- 6685-00-514-3755
===================== Product Identification ===================== Product ID:MERCURY (VARIOUS GRADES) MSDS Date:01/01/1993 FSC:6685 NIIN:00-514-3755 === Responsible Party === Company Name:ADROW CHEMICAL CO. Address:2 LINES AVE. City:WANAQUE State:NJ ZIP:07465-1509 Country:US Info Phone Num:201-839-2372/800-871-0621 Emergency Phone Num:201-337-3183/800-424-9300(CHEMTREC) CAGE:3F134 === Contractor Identification === Company Name:ADROW CHEMICAL CO. Address:2 LINES AVE. Box:City:WANAQUE State:NJ ZIP:07465-1509 Country:US Phone:201-337-3183/201-427-5273 CAGE:3F134 ============= Composition/Information on Ingredients ============= Ingred Name:MERCURY (SARA 313) (CERCLA) CAS:7439-97-6 RTECS #:OV4550000 Other REC Limits:NONE RECOMMENDED OSHA PEL:C, 0.1 MG/M3; Z-2 ACGIH TLV:S,0.025 MG/M3; A4;96 EPA Rpt Qty:1 LB DOT Rpt Qty:1 LB ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:INHAL OF HIGH LEVELS OF MERCURY VAPOR CAN LEAD TO SEVERE RESP IRRIT,CHESGT PAINS,BREATHING DIFFICULTIES WHICH MAY BE FATAL IF RESP IRRIT IS SEVERE.DMG TO CENTRAL NERVOUS SYSTEM,KIDNEYS & LIVER C AN OCCUR.CHRONIC:EXPO TO LOW LEVELS OF MERCURY VAP MAY RESULT IN GUM & MOUTH INFLAMM,IRRITABILITY,TREMORS,(SUPPLEMENTAL) Explanation of Carcinogenicity:PER MSDS:HAS NOT BEEN SHOWN TO CAUSE CANCER. Effects of Overexposure:NERVOUS IRRITABILITY,WEAKNESS,TREMORS,GINGIVITIS,EXCESSIVE SALIVATION,LOOSENING OF TEETH,DEPRESSION,PERSONALITY CHANGES,NERVOUSNESS. Medical Cond Aggravated by Exposure:PEOPLE W/LIVER,KIDNEY,NERVOUS SYTEM DISORDERS SHOULD AVOID EXPOSURE. ======================= First Aid Measures ======================= First Aid:EYE:OCCASIONAL ACCIDENTAL CONTACT W/EYES IS USUALLY HARMFLESS IF WASHED OUT IMMED.HOLD UPPER/LOWER EYELIDS OPEN,WASH EYE THOROUGHLY W/PLENTY OF WATER FOR 15MINS.CONSULT PHYSICIAN.SKIN:WASH EXPO AREA T HOROUGLY W/SOAP/WATER.INHAL:REMOVE PERSON FRM SOURCE OF EXPO TO FRESH AIR.NOT BREATH GIVE ART RESP;BREATH DIFFICULT GIVE OXY.CONSULT DR.INGEST:ACCIDENTAL SWALLOWING/INGEST OF MERCURY USUALLY (SUPPLEM) ===================== Fire Fighting Measures ===================== Flash Point:NA Autoignition Temp:Autoignition Temp Text:NP Lower Limits:NA Upper Limits:NA Extinguishing Media:USE EXTINGUISING MEDIA APPROPRIATE FOR SURROUNDING FIRE. Fire Fighting Procedures:@HI TEMP MERCURY VAPORIZED RAPIDLY TO FORM HIGHLY TOXIC FUMES-COLORLESS/ODORLESS.SHOULD WEAR PROPER PROT EQPMT,SCBA W/FULL FCPIECE OPERATED IN +PRESSURE (SUPPL) Unusual Fire/Explosion Hazard:MERCURY IS NOT FLAMMABLE OR EXPLOSIVE. ================== Accidental Release Measures ================== Spill Release Procedures:USE APPROP RESP PROT/PROPER PROT CLOTH.CLEANUP SPILLS IMMED W/MERCURY VAC CLEANER/OTHER SUITABLE MEANS.DECONTAM AREA W/MERCURY DECONTAMINATES.KEEP COLLECTED MERCURY FOR DISPO.METALLIC MERCURY DROPLETS FRM BROKEN THERMOMETER WILL BECAUSE OFTHEIR(SUP) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP CNTNR TIGHTLY CLOSED.STORE IN COOL DRY AREA AWAY FRM FIRE HAZ.MOVE DMG THERMOMETERS TO WELL VENTI AREA BEF PROCEDDING TO OPEN,THEN FOLLOW MSDS. Other Precautions:MSDS FOR ELEMENTAL HG WHICH IS INTEGRAL COMPONENT OF CLINICAL THERMOMETER.MSDS PROVIDED BY HG SUPPLIER FOR GEN HNDLG OF HG IN LG QUANT.CLINICAL HG THERMOMETER CONSIDERED ARTICLE BY FED GOVT. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:RESPIRATOR FOR PROTECTION AGAINST MERCURY VAPAORS IS NEEDED IS PEL IS EXCEEDED. Ventilation:USE GENERAL OR LOCAL EXHAUST VENTILATION TO MEET PEL REGULATIONS. Protective Gloves:IMPERV GLOVES Eye Protection:GOGGLES TO PROTECT AGAINST SPLASHING Other Protective Equipment:IMPERVIOUS CLOTHING RECOMMENDED.CLOTHING SHOULD BE REMOVED @END OF WORK DAY & WASHED FREQUENTLY. Work Hygienic Practices:NO SMOKING OR EATING IN WORK AREA.SHOWER OR BATHE EVERY DAY. Supplemental Safety and Health FIREFIGHT:MODE WHEN HG INVOLVE IN FIRE. HEALTH:STOMATITIS.CHRONIC EFFECTS OF OVEREXPO CAN RESULT IN DMG TO KIDNEYS,LILVER,CNS. 1STAID:HARMLESS.DONT INDUCE VOMIT.CONSULT DR. SPILL:LIMITED SURF AREA GIV E OFF LIMITED AMTS OF MERCURY VAP IF LEFT UNTOUNCHED;IF TRACKING OD DROPLETS SURF AREA INCR/APPREC AMTS OF HG VAP RELEAS ================== Physical/Chemical Properties ================== HCC:Z2 Boiling Pt:B.P. Text:675F,357C Melt/Freeze Pt:M.P/F.P Text:-36F,-38C Decomp Temp:Decomp Text:NP Vapor Pres:0.273@100C Vapor Density:1.015 Spec Gravity:13.5 pH:NP Viscosity:NP Evaporation Rate & Reference:DEPENDS ON PRESSURE/TEMP Solubility in Water:0.002G/100G @20C Appearance and Odor:SILVERY LIQUID METAL-MOBILE & ODORLESS Percent Volatiles by Volume:NP Corrosion Rate:NP ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES HALOGENS,NITRIC ACID,AMMONIA GAS,ACETYLENE & ACETYLEN PRODUCTS Stability Condition to Avoid:HEAT AND HIGH TEMPERATURE Hazardous Decomposition Products:MERCURY VAPOR ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPO IAW LOC/STATE/FED ENVIRON REGS. BREAK THERMOMETER:WEAR GLOVES TO AVOID SKIN/JEWELRY CONTACT.GATHER HG SPILL/BROKEN GLASS W/HG W/RUBB BALL SYRINGE,DISPO IN CNTNR OF WASTE.WASH IMMED AREA W/PHOSPH ATE SOAP/HG ABSORB POWDER.WASH HANDS IMMED. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.